Put these eight fields on a Type K bare wire RFQ, or the quotes will not compare
Three quotes for the same wire can differ by half and none of them is wrong. What usually happened is that the RFQ described three different products, and each mill priced the product it decided you meant.
Why the same request produces different prices
A wire mill prices what it was asked to make. An RFQ that says only 'Type K wire, 0.20 mm, 10 kg' leaves the mill to choose the diameter tolerance, the temper, the spool length, the tolerance class and the surface condition. Every one of those choices changes the number of drawing passes, the annealing cycle and the scrap rate, so the mill that assumed a loose tolerance and the mill that assumed a tight one are quoting different products. Neither is overcharging.
The fix is not to negotiate harder. It is to remove the choices, so that every mill prices the same object.
The eight fields
These are the fields that actually move a thermocouple wire price. A specification that covers all eight will come back comparable even from mills that never spoke to each other.
| Field | How to write it | What happens if you leave it out |
|---|---|---|
| Grade and grade class | Type K, thermocouple grade (not extension grade) | The mill may quote extension-grade wire at a lower EMF tolerance |
| Diameter and tolerance | Nominal diameter plus an explicit tolerance band | Tight and loose tolerance are different drawing schedules |
| Temper | Annealed, or a stated hardness range | Spring temper and soft temper behave differently on your winder |
| Length per spool | Metres per spool and the spool type | Short spools mean more setup breaks, and setup time is in the price |
| Quantity basis | Kilograms or metres, and whether the quantity is per size or per alloy | Per-size and per-alloy quantities are not the same order |
| EMF tolerance class | Class 1 or Class 2, or the ASTM standard or special limits | A Class 1 quote and a Class 2 quote are not interchangeable |
| Surface condition | Bright, pickled, or as-drawn, and whether lubricant residue is acceptable | Residue has to be removed before a junction is welded |
| Marking and packaging | Batch number on the label, and moisture protection for the spool | Without a batch number the wire cannot be traced to a test record |
Diameter tolerance is the field people skip
Diameter is easy to state and easy to under-specify. Two mills both quoting 0.20 mm may be working to tolerance bands that differ by a factor of two, and the tighter band costs more because it needs more drawing passes, more gauging and a higher rejection rate. If the drawing you are winding does not need the tighter band, say so; if it does, saying so is the only way to compare like with like.
The same logic applies to ovality and to camber. They are rarely written on an RFQ and they are exactly the properties that make a fine wire jam a guide roller.
Temper decides whether the wire runs on your machine
Annealed wire is soft, forms a junction easily and lays flat on a spool. Spring temper holds a shape and feeds better through some automated cut-and-crimp stations, but it is harder to weld without relaxing the end first. If your process assumes one and the quote assumes the other, the wire will arrive wrong even though the diameter and the alloy are right.
State the temper as a condition your process needs, not as a mill term you are guessing at. 'Soft enough to weld without pre-annealing on a 0.20 mm Type K leg' is a usable requirement. 'Annealed' is a word that different mills interpret at different residual hardness.
Tolerance class is a product, not an option
A thermocouple wire pair is only useful if its output follows the published reference table within a stated band. That band is the tolerance class. Class 1 and Class 2 are two different products made to two different acceptance limits, and the tighter class rejects more of the same production run, which is why it costs more. ASTM E230 tabulates the reference EMF and defines the standard and special limits that the classes map onto.
An RFQ that omits the class will be answered at the loosest class the mill is comfortable with, because that is the cheapest honest answer. If your application needs the tighter class, it has to be on the page.
What a usable RFQ looks like
One paragraph is enough if it carries the eight fields. For example: Type K thermocouple-grade bare wire, 0.20 mm nominal with a stated tolerance band, annealed to a weldable condition, spools of a stated length, quantity split by size, Class 1 EMF tolerance, bright surface free of drawing lubricant residue, each spool labelled with the batch number and wrapped against moisture. Ask each mill to quote against that text without substitutions, and note any deviation it proposes.
The last sentence matters more than it looks. Mills that deviate usually have a good reason, and a stated deviation is a technical conversation. An unstated one is a surprise at goods-in inspection.
What a better RFQ does not fix
Clear specifications buy comparability, not quality. Two mills can both meet the written spec and still differ in how evenly the alloy is mixed along the length, how well the two legs are matched, and how the spool survives shipping. Those show up in a sample, not in a quotation. Treat the first order as a sample order and test the thermoelectric output before deciding anything about the second order.
There is also a limit on what a wire mill can promise. A mill controls composition, diameter, temper and surface. It does not control how the wire is welded, how the junction is protected, or what atmosphere the finished sensor sees. Claims about service life belong to the sensor design, not to the spool.
Grade, diameter, quantity, temper. Send those four and a mill can respond the same day. The other four fields decide whether the responses are comparable.
The short version
- Write grade class, diameter tolerance, temper, spool length, quantity basis, EMF class, surface condition and marking.
- Ask each mill to quote without substitution, and to declare any deviation it proposes.
- Expect to test a sample before trusting a second order, however good the paperwork looks.
Is thermocouple grade the same as extension grade?
Does a tighter diameter tolerance improve temperature accuracy?
Why does spool length change the price?
- Type K is a nickel-chromium positive leg against a nickel-aluminium negative leg, and the pair has to be matched to follow the published EMF table.
- ASTM E230 tabulates the reference EMF for standardized thermocouple types and defines the standard and special tolerance limits.
- Diameter tolerance changes the number of drawing passes and the rejection rate, so two mills quoting the same nominal diameter can be quoting different products.
- Class 1 and Class 2 EMF tolerances are different acceptance bands applied to the same production run, not two names for one product.
- Temper affects whether a fine wire welds without pre-annealing and whether it feeds cleanly through an automated cut-and-crimp station.
- Drawing lubricant residue and surface oxide have to be removed before a thermocouple junction is welded.
- A batch number on the spool label is what connects the delivered wire to the test record for that melt.
- A wire mill controls composition, diameter, temper and surface; it does not control welding, junction protection or the atmosphere the finished sensor sees.
Send the specification — diameter, grade, temper, quantity.
We come back with a confirmed lead time and the documentation we can issue for the shipment. 100 g sample at cost; orders from 1 kg.
Request a quotation Order a 100 g sample