XIANYUAlloy · Changzhou
Technical note · 2026-11-04

Put these eight fields on a Type K bare wire RFQ, or the quotes will not compare

Three quotes for the same wire can differ by half and none of them is wrong. What usually happened is that the RFQ described three different products, and each mill priced the product it decided you meant.

Why the same request produces different prices

A wire mill prices what it was asked to make. An RFQ that says only 'Type K wire, 0.20 mm, 10 kg' leaves the mill to choose the diameter tolerance, the temper, the spool length, the tolerance class and the surface condition. Every one of those choices changes the number of drawing passes, the annealing cycle and the scrap rate, so the mill that assumed a loose tolerance and the mill that assumed a tight one are quoting different products. Neither is overcharging.

The fix is not to negotiate harder. It is to remove the choices, so that every mill prices the same object.

The eight fields

These are the fields that actually move a thermocouple wire price. A specification that covers all eight will come back comparable even from mills that never spoke to each other.

FieldHow to write itWhat happens if you leave it out
Grade and grade classType K, thermocouple grade (not extension grade)The mill may quote extension-grade wire at a lower EMF tolerance
Diameter and toleranceNominal diameter plus an explicit tolerance bandTight and loose tolerance are different drawing schedules
TemperAnnealed, or a stated hardness rangeSpring temper and soft temper behave differently on your winder
Length per spoolMetres per spool and the spool typeShort spools mean more setup breaks, and setup time is in the price
Quantity basisKilograms or metres, and whether the quantity is per size or per alloyPer-size and per-alloy quantities are not the same order
EMF tolerance classClass 1 or Class 2, or the ASTM standard or special limitsA Class 1 quote and a Class 2 quote are not interchangeable
Surface conditionBright, pickled, or as-drawn, and whether lubricant residue is acceptableResidue has to be removed before a junction is welded
Marking and packagingBatch number on the label, and moisture protection for the spoolWithout a batch number the wire cannot be traced to a test record

Diameter tolerance is the field people skip

Diameter is easy to state and easy to under-specify. Two mills both quoting 0.20 mm may be working to tolerance bands that differ by a factor of two, and the tighter band costs more because it needs more drawing passes, more gauging and a higher rejection rate. If the drawing you are winding does not need the tighter band, say so; if it does, saying so is the only way to compare like with like.

The same logic applies to ovality and to camber. They are rarely written on an RFQ and they are exactly the properties that make a fine wire jam a guide roller.

Temper decides whether the wire runs on your machine

Annealed wire is soft, forms a junction easily and lays flat on a spool. Spring temper holds a shape and feeds better through some automated cut-and-crimp stations, but it is harder to weld without relaxing the end first. If your process assumes one and the quote assumes the other, the wire will arrive wrong even though the diameter and the alloy are right.

State the temper as a condition your process needs, not as a mill term you are guessing at. 'Soft enough to weld without pre-annealing on a 0.20 mm Type K leg' is a usable requirement. 'Annealed' is a word that different mills interpret at different residual hardness.

Tolerance class is a product, not an option

A thermocouple wire pair is only useful if its output follows the published reference table within a stated band. That band is the tolerance class. Class 1 and Class 2 are two different products made to two different acceptance limits, and the tighter class rejects more of the same production run, which is why it costs more. ASTM E230 tabulates the reference EMF and defines the standard and special limits that the classes map onto.

An RFQ that omits the class will be answered at the loosest class the mill is comfortable with, because that is the cheapest honest answer. If your application needs the tighter class, it has to be on the page.

What a usable RFQ looks like

One paragraph is enough if it carries the eight fields. For example: Type K thermocouple-grade bare wire, 0.20 mm nominal with a stated tolerance band, annealed to a weldable condition, spools of a stated length, quantity split by size, Class 1 EMF tolerance, bright surface free of drawing lubricant residue, each spool labelled with the batch number and wrapped against moisture. Ask each mill to quote against that text without substitutions, and note any deviation it proposes.

The last sentence matters more than it looks. Mills that deviate usually have a good reason, and a stated deviation is a technical conversation. An unstated one is a surprise at goods-in inspection.

What a better RFQ does not fix

Clear specifications buy comparability, not quality. Two mills can both meet the written spec and still differ in how evenly the alloy is mixed along the length, how well the two legs are matched, and how the spool survives shipping. Those show up in a sample, not in a quotation. Treat the first order as a sample order and test the thermoelectric output before deciding anything about the second order.

There is also a limit on what a wire mill can promise. A mill controls composition, diameter, temper and surface. It does not control how the wire is welded, how the junction is protected, or what atmosphere the finished sensor sees. Claims about service life belong to the sensor design, not to the spool.

Four fields for a first enquiry

Grade, diameter, quantity, temper. Send those four and a mill can respond the same day. The other four fields decide whether the responses are comparable.

The short version

  • Write grade class, diameter tolerance, temper, spool length, quantity basis, EMF class, surface condition and marking.
  • Ask each mill to quote without substitution, and to declare any deviation it proposes.
  • Expect to test a sample before trusting a second order, however good the paperwork looks.
Questions we get asked
Is thermocouple grade the same as extension grade?
No. Extension-grade wire is made to a looser EMF tolerance and is intended to carry a signal from the probe to the instrument, not to form the measuring junction. Quoting one against the other is the most common mismatch in an RFQ.
Does a tighter diameter tolerance improve temperature accuracy?
Not directly. Accuracy comes from the alloy pair and its EMF tolerance. Diameter tolerance affects fit, response time and how the wire behaves in your assembly, which is why it still belongs on the RFQ.
Why does spool length change the price?
Every spool change stops the line and produces an end that may not be usable. Short spools mean more breaks for the same tonnage, and that setup time is part of the quoted price.
Citable facts
Sources

Send the specification — diameter, grade, temper, quantity.

We come back with a confirmed lead time and the documentation we can issue for the shipment. 100 g sample at cost; orders from 1 kg.

Request a quotation Order a 100 g sample