XIANYUAlloy · Changzhou
Product family

Thermocouple Wire

Four base-metal types, one discipline: both legs from the same melt, shipped together, with the measured resistance per metre on the spool label.

0.018–6.00Diameter, mm
1 kgMinimum order
3–7 dLead time
100 gSample at cost
TypePositive legNegative legEMF at 500 °CUseful range
KNiCr10 (KP)NiSi (KN)≈ 20.64 mV−200 to 1200 °C
ENiCr10Constantan≈ 37.01 mV−200 to 900 °C
JIronConstantan≈ 27.39 mV0 to 750 °C
TCopperConstantan≈ 20.87 mV (at 400 °C)−200 to 400 °C

The pairing problem

A thermocouple is only as good as the homogeneity of its two legs. If positive and negative come from different melts, the pair develops a parasitic EMF wherever it crosses a temperature gradient — and the controller has no way of knowing it is being told the wrong number. Drawing both legs from the same melt, and shipping them together, removes that variable at the source.

What we supply

ParameterRange
Diameter0.018 – 6.00 mm
Tolerance classClass 1 or Class 2 to IEC 60584-1
Supply formMatched pair, spooled or coiled
Spool labelGrade, diameter, net weight, measured Ω/m, date, checker
Minimum order1 kg
Lead time3–7 days
0.018 mm

The finest gauge we draw in routine production. Every spool leaves with a label recording the measured resistance per metre — 5 174 Ω/m on the 0.018 mm NiCr20AlSi spool shown on our home page, dated and signed by the checker. It is an identification label, not a certificate; measured values are confirmed on the inspection report.

Grades in this family

Pick the designation your drawing cites

Type K

Type K Thermocouple Wire

The most widely used base-metal thermocouple. Positive leg NiCr (KP), negative leg NiSi (KN). We draw both legs from the same melt and ship them toget…

Type E

Type E Thermocouple Wire

The highest EMF output of the base-metal thermocouples — roughly 68 µV/K — which makes it the practical choice when the readout has limited resolution…

Type J

Type J Thermocouple Wire

Iron positive leg, constantan negative. Cheap, sensitive, and widely used in older plant and in equipment built to legacy drawings — but the iron leg …

Type T

Type T Thermocouple Wire

Copper positive, constantan negative. The most stable of the base-metal types at low temperature, and the usual choice for cryogenic work, cold-chain …

Questions we get asked
Do you supply extension and compensating wire?
Yes — KX, EX, JX and TX lead wire is drawn from matching alloy, and we quote it alongside the thermocouple wire.
How do I know the pair is matched?
Both legs carry the same melt number on the label and on the inspection report. That is the document your quality engineer will ask for.

Send the specification — diameter, grade, temper, quantity.

We come back with a confirmed lead time and the documentation we can issue for the shipment. 100 g sample at cost; orders from 1 kg.

Request a quotation Order a 100 g sample