XIANYUAlloy · Changzhou
Technical note · 2026-10-27

A 0.4 % shift after soldering is almost never the manganin

Four thousand ppm of resistance change is what 0.4 % means, and manganin's own temperature coefficient is only ±10 ppm/K, so the alloy would have to sit 400 K hotter to move that far on its own. Its documented permanent shift starts above 140 °C, which a three-second solder joint does not reach. Something else moved: the temperature you measured at, the solder joint now inside your sense loop, or the element temperature during a bake or a second reflow. Check them in that order before you replace the wire.

Put a number on 0.4 % before blaming the alloy

0.4 % is 4000 ppm. Manganin's temperature coefficient of resistance is ±10 ppm/K between 20 and 50 °C, so an alloy-only explanation needs a 400 K excursion. That is not a soldering event, it is a furnace run. The same arithmetic applied to the finished component gives a very different answer, because the measured temperature coefficient of a low-value shunt is not the alloy's.

At 500 µΩ, a shunt's as-measured coefficient is typically ±100 to ±400 ppm/°C, roughly ten times the alloy figure, because the copper terminations sit in series with the element and copper's coefficient is strongly positive. At 200 ppm/°C, 0.4 % is a 20 K difference. On a 100 µΩ CuMn12Ni part measured at 106 ppm/°C, it is 38 K. Both are ordinary workshop temperature differences, not metallurgy.

What soldering actually does to the element

The published limit is unambiguous: manganin holds a stable resistance in air up to about 140 °C, and above that limit the alloy anneals and the change becomes permanent. Below 80 °C the element is stable enough that datasheets stop quoting drift. Recommended maximum element temperature for accuracy work is 80 °C, with 125 °C the practical ceiling and 140 °C the point of no return.

A hand solder joint at 250 °C lasts two or three seconds and heats a copper terminal with far more thermal mass than the element. The element does not follow. Sustained heat is a different story: a 100 µΩ CuMn12Ni shunt held 168 hours at 200 °C gained 1.85 % when untrimmed and 2.29 % when trimmed, with surface oxygen rising from about 3.4 % to 5.5 % by weight. If your board went through potting cure, a second reflow, or a hot plate, you have run that experiment at low dose.

The four places 0.4 % actually comes from

  • Measurement temperature. If the pre-solder value was recorded at 23 °C and the post-solder value at 45 °C, 0.4 % is arithmetic, not damage.
  • Solder joints inside the sense loop. A joint with its pad and trace can reach 0.25 mΩ; on a 25 mΩ shunt that is 2 % before any other term, and joints are the least repeatable part of the assembly.
  • Sense-point geometry after rework. Moving the sense tap from the element to the pad adds the termination copper to the measurement, which changes both the value and its temperature coefficient.
  • Flux residue. Aggressive flux left on a precision element corrodes the wire and alters resistance over weeks, not seconds.

A diagnosis you can run in ten minutes

Re-measure the part cold, at the same temperature as the reference value, four-wire, with the sense taps on the element and not on the pads. If the number returns, you had two different temperatures and the part is fine. If it does not, measure the resistance between the two original sense points and between the pads, and take the difference; that difference tells you whether you are looking at a joint or at the element.

Only then consider heat damage. Look for discoloured terminals, burnt flux, or a reflow profile with two passes over the same part. A part that genuinely sat above 140 °C cannot be re-trimmed back into calibration, because the resistivity and the temperature coefficient have both moved; replace it and fix the process that overheated it.

The honest split

If the part stayed under 140 °C and the error survives a careful four-wire measurement at a known temperature, the manganin is not the cause and a new spool will not fix it. If the part did exceed 140 °C, no amount of recalibration will bring it back, because annealing changes the alloy itself. The two cases look identical on a report and have opposite remedies.

What to change in the process, not the purchase order

Calibrate after assembly, never before. Precision resistance alloys are artificially aged — held for hours near 120 to 140 °C — specifically so that the value settles before it is trimmed or certified; soldering after calibration undoes that work. For joining, brazing is preferred over soldering on precision parts, and when brazing is used the filler should melt as low as possible and the dwell should be as short as possible, because heating shifts both resistivity and temperature coefficient. Where soldering is unavoidable, use a lead-free solder, keep the joint short, clamp a heat sink on the terminal, and remove every trace of flux.

The wire supplier's part of this is narrower than most buyers expect: composition, resistivity at a stated temperature, measured temperature coefficient, and a certificate per batch. A mill can tell you the alloy arrived at 0.43 µΩ·m and ±10 ppm/K. It cannot tell you why your assembled shunt reads 0.4 % high, and a supplier who offers to is guessing.

Questions we get asked
Can a normal solder joint permanently change manganin's resistance by 0.4 %?
Not on its own. A two- or three-second joint at 250 °C does not hold the element above the 140 °C point where manganin anneals, because the copper terminal has far more thermal mass. A permanent 0.4 % shift requires sustained heating such as potting cure, a second reflow, or a hot plate, not a single joint.
How do I tell a permanent shift from a measurement artefact?
Re-measure four-wire at the same temperature the original value was taken at, with the sense taps on the element rather than the pads. If the value returns, the difference was temperature. At 200 ppm/°C on a 500 µΩ part, a 20 K difference alone accounts for 0.4 %.
Does tin-lead or lead-free solder matter for a precision shunt?
Both work, but lead-free is preferred on precision parts and the dwell matters more than the alloy. Aggressive flux residue is the bigger risk: it corrodes the element and changes resistance over time, so every trace has to be removed after joining.
Should I calibrate the shunt before or after soldering?
After, always. Resistance alloys are artificially aged near 120 to 140 °C so the value settles, and any joining heat applied after calibration reopens that settling. Calibrating before assembly means calibrating a part that has not finished changing.
Citable facts
Sources

Send the specification — diameter, grade, temper, quantity.

We come back with a confirmed lead time and the documentation we can issue for the shipment. 100 g sample at cost; orders from 1 kg.

Request a quotation Order a 100 g sample