Bare wire, insulated wire or MI cable: pick by what happens after delivery

These three are often compared as if they were grades of the same product. They are not. One is a component you build a sensor from, one is a cable that carries a signal, and one is a sealed assembly that survives an environment. The choice follows from the step after delivery, not from the temperature on the process sheet.

The three products, stated plainly

Bare wire is uninsulated thermocouple alloy, supplied on a spool. It is the raw material for a measuring junction: the buyer welds the two legs together, mounts them, and provides insulation separately through ceramic beads, a protection tube or a coating.

Insulated thermocouple cable is the same alloy pair with a dielectric covering, sometimes a shield and an outer jacket. It is used to carry the signal from the junction to the instrument, or to build a probe where the insulation is part of the design. The alloys may be the measuring grade or the cheaper extension grade.

Mineral-insulated cable is a different construction: the alloy conductors sit inside a metal sheath, packed with compacted magnesium oxide. The sheath seals the assembly against moisture and pressure, and the oxide holds the conductors in place. It is bought as cable and usually finished into a probe.

The comparison that actually decides it

PropertyBare wireInsulated cableMI cable
What it is forBuilding a junctionCarrying a signalSurviving an environment
Seals against moistureNoDepends on jacket and terminationsYes, by the metal sheath
Maximum temperatureLimited by the alloy and atmosphereLimited by the insulation materialLimited by sheath alloy and the oxide
Response timeFast, low thermal massModerateSlower, the sheath adds mass
FlexibilityVery flexibleFlexible to stiff by constructionBends to a minimum radius, not repeatedly
Field repairableYes, cut and re-weldUsually yesNo, a damaged sheath ends the assembly
Typical buyerSensor manufacturerPanel builder or probe makerProcess plant or probe fabricator

Read the table down the first column rather than across the temperature row. Buyers who start with the maximum temperature usually end up buying the most expensive construction they do not need.

Mistake one: comparing prices across the three

A bare wire quote and an MI cable quote are not two prices for the same thing, and treating them as competitors produces a decision that has to be reversed later. The bare wire price excludes the insulation, the sheath, the compaction, the end sealing and the testing that the MI cable price already contains. If a project genuinely needs a sealed assembly, the cheaper option is not cheaper; it is the first half of the expensive option.

The reverse error is just as common: buying MI cable for a laboratory rig where a bead-insulated bare junction would respond faster and cost less. The sheath mass slows the response, and in a rig where the temperature is changing quickly that lag is the measurement error.

Mistake two: stripping insulated wire and using it as bare wire

It works once and fails quietly. Insulation residues and the deformed conductor left by stripping contaminate the weld zone and change the local alloy composition at exactly the point that generates the EMF. The junction may still read plausibly at room temperature and drift at temperature, which is the hardest kind of fault to trace. If the process needs bare wire, buy bare wire.

Mistake three: bending MI cable like a cable

Compacted magnesium oxide holds its insulating value because it is compacted. Bend the sheath past its minimum radius, or bend the same spot repeatedly, and the packing loosens locally. The result is a drop in insulation resistance that may only appear after the assembly is hot, or after moisture has had time to migrate along the sheath. Sheathed thermocouple cable has its own test methods for exactly this reason, and a fabrication drawing should state the bend radius rather than leave it to the fitter.

A short decision path

  • If you weld the junction yourself and provide insulation in your own design, buy bare wire.
  • If the run leaves the probe and the environment is dry and moderate, buy insulated cable, and decide measuring grade versus extension grade on purpose.
  • If the joint will see moisture, pressure, vibration or washdown, buy MI cable and design the termination as part of the assembly.
  • If you need a fast response and a sealed joint, the answer is usually a small-diameter sheathed assembly, not a bare junction with a coating.

What the wire mill can and cannot answer

A mill drawing thermocouple alloy can answer questions about composition, diameter, temper, surface and the EMF tolerance of the pair it supplies. It cannot tell you whether an MI assembly will hold insulation resistance after a year in your process, because that depends on the sheath alloy, the compaction, the termination and the thermal cycling. Ask the mill for wire properties and ask the assembly fabricator for assembly behaviour; a single supplier answering both questions is usually estimating one of them.

This is also where certificates get confused. A material certificate for the wire covers the wire. It says nothing about the finished cable assembly, and nothing about the junction that will be welded from it.

The one question that settles it

Does anything after delivery need to keep moisture away from the alloy? If yes, the product is a sealed construction, not a bare wire with good intentions.

The short version

  • Bare wire is a component, insulated cable is a signal path, MI cable is a sealed assembly.
  • Compare prices only within one construction.
  • Do not strip insulated wire to make a junction, and do not treat an MI bend radius as a suggestion.
Questions we get asked
Can I use extension-grade cable for the whole run, including the junction?
No. Extension grade is intended to carry a signal from an existing junction to the instrument, and its EMF tolerance is looser. Forming the measuring junction from extension-grade wire puts that looser tolerance directly into the measurement.
Is MI cable always the better choice for high temperature?
It is the better choice when the joint must also be sealed. If the atmosphere is clean and dry, a bare or bead-insulated junction can run hotter and respond faster than an MI assembly with the same conductor alloy, because there is no sheath between the junction and the process.
Does a metal sheath make an MI thermocouple grounded?
Only if the sheath is bonded to the conductors or to the process. Sheath, junction and grounding arrangement are design choices, and they need to be stated on the assembly drawing rather than assumed.