Type K vs Type E

Type E gives you nearly twice the signal. Type K gives you twice the range. Almost every other difference follows from those two facts.

Type KType E
Positive legNiCr10NiCr10
Negative legNiSiConstantan
EMF at 100 °C≈ 4.10 mV≈ 6.32 mV
EMF at 500 °C≈ 20.64 mV≈ 37.01 mV
Approx. sensitivity≈ 41 µV/K≈ 68 µV/K
Useful range−200 to 1200 °C−200 to 900 °C
Drift in oxidising serviceGreen-rot in reducing atmospheresBetter stability at low temperature

Why type E has the bigger signal

Both types share the same positive leg. The difference is on the negative side: constantan has a much larger Seebeck coefficient against NiCr than NiSi does. That is the whole mechanism — and it is also why type E's negative leg is the same wire used as the negative leg of types J and T.

Where type K still wins

  • Above 900 °C, where type E is out of its range
  • Where the thermocouple must survive thermal cycling in air
  • Where the installed base and the controllers already assume type K
One practical warning

Type K's negative leg is prone to "green rot" in reducing atmospheres and to short-range ordering effects around 250–550 °C. If your process is a vacuum furnace with a carbon environment, that is worth designing around rather than discovering.

Questions we get asked
Can I use the same constantan for type E, J and T?
Yes — the negative leg is constantan in all three. The positive leg is what changes, which is convenient for a probe maker stocking one negative wire.
Which drifts less at low temperature?
Type E and type T are both better than type K below ambient. Type T is usually preferred for cryogenic work because copper behaves predictably there.